DABL-63 RCBO 6KA Residual current operated circuit breaker
DABL-63 RCBO 6KA Residual current operated circuit breaker

DABL-63 RCBO 6KA Residual current operated circuit breaker

Residual current operated circuit breakers with overcurrent protectionDABL-63 are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection.
They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.

Contact Us

Tel:+86-21-57467000
Email:charlotte.weng@cdada.com
Skype:charlott0315
QQ:979638227

DABL-40 series Residual current operated circuit breakers with overcurrent protection

>> Introduction


 

Residual current operated circuit breakers with overcurrent protectionDABL-40are intended for electric shock hazard protection in case of electric installation insulation failures, for preventing fires caused by earth current leakages, overload and short circuit protection. 
They are recommended for protecting group lines supplying outdoor installation receptacles, appliances and garage and basement lighting.


>> Advantages


·  Combined circuit with an electronic module of differential protection and integrated circuit breaker of DAB7-63 series.

·  The most subtle electric shock hazard protection in case of direct contact with conducting parts.

·  Independent contact position indicator.

·  Wide range of operating temperatures from –25 to +40° С.

·  Notches on terminal clamps provide for lowering thermal losses and boosting the mechanical stability of connection.

·  “TEST” button for checking the device’s operation and accuracy of connection.

·  DABL dimensions correspond to 2-modular item at the expense of constructive elements placement.

·  Boosted capability of 6 kA provides for installing AVDTs as incoming protection switches.


>> Design Features

Combined circuit with an electronic module of differential protection, D-class varistor and integrated circuit breaker of DAB7-63 series ensures 4 types of protection: from residual current (leakage current), short circuit; overload and surge overvoltage.

 

Welding deposition of silver-bearing composite provides for boosting the contact block’s wear-resistance and lowering the transient one.

 

Main circuit status indicator provides exact information on the contacts status independently from lever position.

 

Wide range of operating temperatures from –25 to +40° С contributes to applying this switch in different climatic zones.

 

“TEST” button for checking the device’s operation and accuracy of connection.

 

Notches on terminal clamps allow lowering thermal losses and boosting the mechanical stability of connection.

  

Boosted screw head dimension with cross-functional crest (+,–) helps to facilitate mounting and prevents the screws from falling out during the installation.