DAB7N-40 6KA DPN Miniature Circuit breaker
DAB7N-40 6KA DPN Miniature Circuit breaker
DAB7N-40 6KA DPN Miniature Circuit breaker

DAB7N-40 6KA DPN Miniature Circuit breaker

DAB7N-40 Series miniature circuit breaker adopts double-break point of 1P+N,the two poles are insulated and isolated from each other,under synchronous operation,N-pole always will make first and break later, which guarantees electric arc breaking capacity of protected pole, also ensures safety of controlled circuits and electric equipment.

Contact Us

Tel:+86-21-57467000
Email:charlotte.weng@cdada.com
Skype:charlott0315
QQ:979638227

DAB7N-40 series DPN Miniature Circuit breaker(MCB)


>> Introduction


 

DAB7N-40 Series miniature circuit breaker adopts double-break point of 1P+N,the two poles are insulated and isolated from each other,under synchronous operation,N-pole always will make first and break later, which guarantees electric arc breaking capacity of protected pole, also ensures safety of controlled circuits and electric equipment.


>> Advantages

·  Two types of overcurrent protection – thermal and electromagnetic.

·  Independent contact position indicator.

·  DIN rail latch with a double fixed position.

·  Wide range of operating temperatures from –40 to +50° С.

·  Wide engagement lever with improved contact area.

·  Notches on terminal clamps lower thermal losses and boost the mechanical stability of connection.


>> Electrical parameters of DAB7N-40 miniature circuit breaker
Standard of conformity: IEC60898, GB10963
Rated power: 50-60HZ
Rated voltage: 230V
Rated current: 40A
Rated insulation voltage: 500V
Impulse withstand voltage: 4KV
Endurance: no less than 180,000 times of on-off
Instantaneous trip type: B/C
Rated breaking capacity: 6
Release type: thermo-magnetic


>> Mechanical parameters of DAB7N-40 miniature circuit breaker
Protection grade: IP20
Electric wire: 1~35mm2
Working temperature: -5~+40℃
Flame retardant grade: grade2
Altitude: ≤2000
Class of pollution: 2
Installation environment: Avoid obvious shock and vibration
Installation grade: grade II
Installation method: Using 35mm guide rail according to IEC standard
Terminal type: Dual-purpose terminal can be connected to the bus bar and conductor.
Terminal connection ability: conductor 1-25mm2, bus bar thickness 0.8-2mm
Guide rail: DIN35guide rail


>> Technical Features

MCB DAB7-40

For protection of general power distribution (IEC/EN 60898-1)

Poles

1P

Electrical performance

Functions

short circuit protection,overload protection,isolationg,control

Rated frequency f(Hz)

50-60Hz

Rated working voltage Ue(V)AC

230

Rated current In ( A)

40

Rated insulated voltage Ui( V)

500

Impulse withstand voltage Uimp(kV)

4

Instantaneous tripping type

B/C

Rated short circuit Icn(kA)                       

DAB7-40

6

Release type

Thermal magnetic type

Service life(O~C)

Mechanical

 Actual value

12000

 Standard value

4000

Electrical

 Actual value

6000

 Standard value

4000

Connection and installation

Protectiom degree

IP20

Wire                                            mm²

1~35

Working temperature

-5~+40℃

Resistance to humidity and heat

Class 2

Altitude above sea

≤2000

Relative humidity

+20℃,≤90% ;+40℃,≤50%

Pollution degree

2

Installation environment

Avoid obvious shock and vibration

Installation class

ClassⅡ, ClassⅢ

Mounting

DIN35 rail

Combination with accessories

Auxiliary contact

Yes

Alarm contact

Yes

Shunt release

Yes

Undervoltage release

Yes

Auxiliary contact+Alarm contact

Yes

Dimensions(mm)  (WxHxL)         

a

18

b

80.7